Vibration analysis in middle ear model with artificial ossicles, total ossicular replacement prosthesis (TORP) by holographic interferometry.
نویسندگان
چکیده
منابع مشابه
[Vibration analysis in middle ear model with artificial ossicles, total ossicular replacement prosthesis (TORP) by holographic interferometry].
Vibration of tympanic membranes of the middle ear model with TORP and flat membrane made of gum were studied by means of holographic interferometry. Results were as follows. 1) As the tension of the gum became high, the amplitude decreased in low frequency. The segmental vibration was observed in low frequency as the tension became low. 2) The difference between 0.03mm and 0.06mm was not signif...
متن کاملDynamic study of the middle ear using a total ossicular replacement prosthesis
Among the many existing hearing problems, there are those that need to be corrected through the replacement of the ossicles of the middle ear with a prosthesis. The type of the prosthesis used in the rehabilitation of the middle ear, total ossicular replacement prosthesis (TORP) or a partial ossicular replacement prosthesis (PORP) depends of the level of the ossicular impairment [1,2]. In the p...
متن کاملComparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis
Introduction: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, w...
متن کاملPediatric ossiculoplasty with titanium total ossicular replacement prosthesis.
OBJECTIVES/HYPOTHESIS To assess the medium-term efficacy of total ossicular reconstruction with a titanium total ossicular replacement prosthesis (TORP) in children. STUDY DESIGN Case series. METHODS A consecutive series of children receiving an adjustable-length titanium TORP was identified from a prospective surgical and audiological database. Audiometric testing was obtained preoperative...
متن کاملAuditory effects of autologous fat graft for TORP stabilization in the middle ear: a cadaveric study
BACKGROUND Total ossicular replacement prostheses (TORP) are often used to re-establish ossicular coupling of sound in an ear lacking a stapes supra-structure. The use of TORPs, however, is associated with a 2/3 five year failure rate due to their anatomic instability over time in the middle ear. The use of autologous fat to try and stabilize TORPs may improve long-term results with this challe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nippon Jibiinkoka Gakkai Kaiho
سال: 1987
ISSN: 0030-6622,1883-0854
DOI: 10.3950/jibiinkoka.90.536