Verification of radiodynamic therapy by medical linear accelerator using a mouse melanoma tumor model
نویسندگان
چکیده
منابع مشابه
Medical Isotope Production Using A 60 MeV Linear Electron Accelerator
Medical isotopes can be produced by reactors and accelerators [1]. For certain isotopes there could be an advantage to a certain production method. For example; in some cases production via the ( ,n) or ( ,p) reaction has advantages that include high production yield [2] and production in a matrix that simplifies chemical separation of the desired isotope. To maximize isotope production, a high...
متن کاملEstablishment of linear accelerator-based image guided radiotherapy for orthotopic 4T1 mouse mammary tumor model
This study was conducted to assess the feasibility of image guided radiotherapy (IGRT) for orthotopic 4T1 mouse mammary tumor using linear accelerator (LINAC). Eighteen Balb/C mice were inoculated with 4T1 cells on left mammary fat pad and nine of them were irradiated using LINAC. Tumors, planning target volumes (PTV), bowels adjacent to tumors, bones and lungs were delineated on planning CT im...
متن کاملautomatic verification of authentication protocols using genetic programming
implicit and unobserved errors and vulnerabilities issues usually arise in cryptographic protocols and especially in authentication protocols. this may enable an attacker to make serious damages to the desired system, such as having the access to or changing secret documents, interfering in bank transactions, having access to users’ accounts, or may be having the control all over the syste...
15 صفحه اولMega Voltage Cone Beam Computed Tomography (MV- CBCT) using a Standard Medical Linear Accelerator and EPID: A feasibility study.
Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...
متن کاملa study on insurer solvency by panel data model: the case of iranian insurance market
the aim of this thesis is an approach for assessing insurer’s solvency for iranian insurance companies. we use of economic data with both time series and cross-sectional variation, thus by using the panel data model will survey the insurer solvency.
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2018
ISSN: 2045-2322
DOI: 10.1038/s41598-018-21152-z