Verification of calculations carried out with the Eclipse treatment planning system
نویسندگان
چکیده
منابع مشابه
Verification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet
Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...
متن کاملPlanning for mARC treatments with the Eclipse treatment planning system
While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of c...
متن کاملTreatment Couch Modeling in the Treatment Planning System Eclipse
The treatment couch and some of the positioning devices of patients receiving radiotherapy treatment are made of a material (carbon) which has low attenuation properties for the photon energies used in the radiotherapy. Previous investigations showed the suitability of carbon fiber tabletops in radiotherapy and their very low attenuation properties for a range of X-ray energies and field sizes ...
متن کاملVerification of tangential breast treatment dose calculations in a commercial 3D treatment planning system
The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...
متن کاملEvaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...