Variation of Fixation Direction with Colour of Fixation Target
نویسندگان
چکیده
منابع مشابه
Variation of fixation direction with colour of fixation target.
IN the course of recording eye movements it has become evident that the fixation direction of the eye changes slightly when the colour of the fixation target is changed. The technique used is that described by Ditchburn and Ginsborg (1953), photographing the movements of a beam of light reflected from a mirror attached to a contact lens worn by a subject. Several modifications as described by F...
متن کاملClinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique
Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...
متن کاملDirection perception and human fixation eye movements.
The existence of involuntary movements of the eye during fixation gives rise to a problem concerning location m visual space. This has been investigated using a psychophysical task in which subJects judge the relative positions of two stimuli briefly flashed on a screen gnd separated by a temporal interval. It was shown, in line with the work of Matin (1972). that a subject’s ability to compare...
متن کاملFunctional Outcome of Internal Fixation of Radial and Ulna Fracture
Background: Displaced fractures of radius and ulna bones in adults are usually treated with open reduction and internal fixation. The purpose of this research was to access functional outcome of these fractures. Materials and Methods: In this research 52 Patients who underwent ORIF with DCP 3.5 in past 5 years were investigated. Post-operation protocol was one week immobilization and then acti...
متن کاملMeasurement of the immobilisation efficacy of a head fixation system
Background: In order to assign appropriate planning target volume (PTV) margins, each centre should measure the patient positioning deviations for their set-up techniques. At the Royal Marsden Hospital, UK, a conformal shell (cast) system is used when a stereotactic frame is not suitable. In this paper, we report on a series of measurements with the aim of obtaining the systematic and random ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Ophthalmology
سال: 1955
ISSN: 0007-1161
DOI: 10.1136/bjo.39.5.294