Modeling and Control Strategy for Variable Speed Wind Turbine Using Permanent Magnet Synchronous Generator
This paper proposes an optimized model and control strategy for variable speed wind turbine using permanent magnet synchronous generator (PMSG). Models and equations that describe different components of the wind energy conversion system (WECS) are addressed and their implementations into PSCAD/EMTDC are described. There are different types of synchronous generators, but the PMSG is chosen. It ...
متن کاملAnalysis and Design of a Permanent-Magnet Outer-Rotor Synchronous Generator for a Direct-Drive Vertical-Axis Wind Turbine
In Permanent-Magnet Synchronous Generators (PMSGs) the reduction of cogging torque is one of the most important problems in their performance and evaluation. In this paper, at first, a direct-drive vertical-axis wind turbine is chosen. According to its nominal value operational point, necessary parameters for the generator is extracted. Due to an analytical method, four generators with differen...
متن کاملWind Turbine Driven by Permanent Magnet Synchronous Generator
A permanent magnet synchronous generator (PMSG) variable speed wind turbine connected to an electrolyzer and a battery model system is presented in this paper. Hydrogen gas could be produced from the model system, when a variable wind speed is applied to the PMSG driven variable wind turbine. The simulation results presented shows the nature of some of the variables of the PMSG wind driven turb...
متن کاملFlicker Mitigation by Speed Control of Permanent Magnet Synchronous Generator Variable-Speed Wind Turbines
Grid-connected wind turbines are fluctuating power sources that may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a full-scale back-to-back power converter and permanent magnet synchronous generator (PMSG) developed in the simulation tool of PSCAD/EMTDC. Flicker emission of this system is investigated. The 3p (...
متن کاملActive and Reactive Power Management of Grid Connected Variable Speed Permanent Magnet Generator Wind Turbine
In this paper a variable speed generating unit is considered, equipped with permanent magnet generator. The system analysis involves appropriate models for the generator, the static converter and the grid. Moreover, an asynchronous generator mounted on the same rotor with dump loads ensures braking actions and management of the active power produced. The modelling of the generator and power ele...