Vapor Pressure Measurement of Zinc Oxychloride
نویسندگان
چکیده
منابع مشابه
Pressure Dependence of Liquid Vapor Pressure: An Improved Gibbs Prediction
A new model for the vapor phase of a pressurized liquid called "the cluster model: which is originally introduced in this work, along with an accurate equation of state for the liquid phase called the LIR, is used to derive an accurate equation for the vapor pressure of liquid as a function of external pressure. The chemical Potential of both phase have been found to be in good agreement wi...
متن کاملA New Vapor Pressure Equation
The Wagner equation for prediction of vapor pressure has been modified in order to improve it accuracy. On the basis of this modifications, development of a new equation for prediction of vapor pressure is outlined. Examples of the use of the equation for obtaining vapor pressure for a total of 94 pure substance are given. The proposed equation combines simplicity and accuracy and performs as w...
متن کاملShape Evolution of Layer-Structured Bismuth Oxychloride Nanostructures via Low-Temperature Chemical Vapor Transport
Chemistry of Materials is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Article Shape Evolution of Layer-Structured Bismuth Oxychloride Nanostructures via Low-Temperature Chemical Vapor Transport Hailin Peng, Candace K. Chan, Stefan Meister, Xiao Feng Zhang, and Yi Cui Chem. Mater., 2009, 21 (2), 247-252• DOI: 10.1021/cm802041g • Publication Date (...
متن کاملPlasma-enhanced chemical vapor deposition of zinc oxide at atmospheric pressure and low temperature
The plasma-enhanced chemical vapor deposition of aluminum-doped zinc oxide has been demonstrated for the first time at 800Torr and under 250 1C. A film resistivity of 3 10 2 O cm and a transparency of 95% from 375 to 2500 nm was obtained for deposition at 20mTorr diethylzinc, 1.0 Torr CO2, 799Torr He, a TMAl/DEZn ratio of 1:100, 41W=cm RF power, and 225 1C. The average aluminum concentration in...
متن کاملMeasurement and Modeling of High Pressure Vapor-liquid Equilibria of Co2 + Alcohol Binary Systems
A new apparatus based on a static-analytic method was developed in this work to perform high-pressure vapor-liquid equilibria measurements up to 68 MPa and 373 K. In order to validate this new apparatus, vapor-liquid equilibria of the binary system CO2 + ethanol was measured at temperatures of 313, 323 and 338 K and pressures from 1.2 to 11 MPa. Results were compared with data from the literatu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ISIJ International
سال: 2003
ISSN: 0915-1559
DOI: 10.2355/isijinternational.43.1356