Validation and calibration of dynamic energy models: energy audit of a public building
نویسندگان
چکیده
Abstract Detailed buildings energy audits require dynamic simulation models based on hourly input data. This paper presents the calibration and validation of an office building model for heating cooling services. Simulation are carried out by DesignBuilder software. Measured supplied generation system used model. Employee behaviour with reference to occupancy profiles indoor temperature settings is also considered. A good agreement between measured simulated data obtained both seasons.
منابع مشابه
the role of russia in transmission of energy from central asia and caucuses to european union
پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...
15 صفحه اولsupply and demand security of energy in central asia and the caucasus
امنیت انرژی به معنی عرضه مداوم و پایدار همراه با قیمت های معقول در حامل های انرژی، که تهدیدات امنیتی، سیاسی، اقتصادی، محیط زیستی و روانی را کاهش دهد. امروزه نفت و گاز تنها، کالای تجاری نیست بلکه بعنوان ابزار سیاسی مورد استفاده قرار می گیرد.اختلاف میان روسیه و اکراین بر سر انرژی در ژانویه 2006، تهدیدی برای امنیت انرژی اروپا ایجاد کرد. در این تحقیق ما تلاش کردیم که نقش انرژی آسیای میانه و قفقاز ر...
15 صفحه اولAn Approach to the Calibration of Building Energy Simulation Models
As part of the model validation and development activities of a European research initiative in the area of passive solar architecture, a validation/calibration methodology has been developed which emphasises the use of empirical data in the model proving process and, if necessary, model calibration before use. This procedure has been applied to the ESP-r system in order that it might be used t...
متن کاملEnergy efficiency in a building complex through seasonal storage of thermal energy in a confined aquifer
Confined aquifers are formations surrounded by impermeable layers called cap rocks and bed rocks. These aquifers are suitable for the seasonal storage of thermal energy. A confined aquifer was designed to meet the cooling and heating energy needs of a residential building complex located in Tehran, Iran. The annual cooling and heating energy needs of the buildings were estimated to be 8.7...
متن کاملconstruction and validation of a computerized adaptive translation test (a receptive based study)
آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of physics
سال: 2021
ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']
DOI: https://doi.org/10.1088/1742-6596/2116/1/012107