Vacuum-UV negative photoion spectroscopy of CH4
نویسندگان
چکیده
منابع مشابه
Vacuum-UV negative photoion spectroscopy of CF3Cl, CF3Br, and CF3I.
Using synchrotron radiation, negative ions are detected by mass spectrometry following vacuum-UV photoexcitation of trifluorochloromethane (CF(3)Cl), trifluorobromomethane (CF(3)Br), and trifluoroiodomethane (CF(3)I). The anions F(-), X(-), F(2)(-), FX(-), CF(-), CF(2)(-), and CF(3)(-) are observed from all three molecules, where X = Cl, Br, or I, and their ion yields recorded in the range of 8...
متن کاملSwiss Light Source VUV beamline, Imaging photoelectron photoion coincidence spectroscopy
An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or ambient temperature gas-phase sample. Photoelectrons are velocity focused, with a resolution better than 1 meV in order to detect threshold electrons. ...
متن کاملImaging photoelectron photoion coincidence spectroscopy with velocity focusing electron optics.
An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or thermal gas-phase sample. Photoelectrons are velocity focused, with better than 1 meV resolution for threshold electrons, and also act as start signal ...
متن کاملPFI - ZEKE spectroscopy using coherent vacuum UV : 0 ; ( a “ II , ) - 02
The PFI-ZEKE spectra of the first four vibrational levels of O;(a “n,) are reported. The rotationally resolved photoelectron spectra were assigned by diagonalizing the appropriate Hamiltonian in a Hund’s case a basis set. An extension of a previous model for rotational line strengths (the BOS model) to the intermediate coupling case was applied to the three vibrational bands with v+ = 1-3. As h...
متن کاملField detection of CO and CH4 by NIR 2f modulation laser spectroscopy
A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Molecular Physics
سال: 2010
ISSN: 0026-8976,1362-3028
DOI: 10.1080/00268970903535483