Expiratory flow limitation detected by forced oscillation and negative expiratory pressure.
The within-breath change in reactance (Delta(rs)) measured by forced oscillation technique (FOT) at 5 Hz reliably detects expiratory flow limitation in chronic obstructive pulmonary disease (COPD). The present study compared this approach to the standard negative expiratory pressure (NEP) method. In total, 21 COPD patients were studied by applying both techniques to the same breath and in 15 pa...
متن کاملPositive expiratory pressure and oscillatory positive expiratory pressure therapies.
Airway clearance techniques, historically referred to as chest physical therapy, have traditionally consisted of a variety of breathing maneuvers or exercises and manual percussion and postural drainage. The methods and types of airway clearance techniques and devices have rapidly increased in an effort to find a more efficacious strategy that allows for self-therapy, better patient adherence a...
متن کاملPositive end-expiratory pressure.
PURPOSE OF REVIEW In the last 2 years, several reports have dealt with recruitment/positive end-expiratory pressure (PEEP) selection. Most of them confirm previous results and few add new information. RECENT FINDINGS It has been definitely confirmed that opening pressures are different throughout the acute respiratory distress syndrome lung parenchyma, ranging from 5-10 up to 30-40 cmH2O. The...
متن کاملExtrathoracic expiratory flow limitation in obesity and obstructive and restrictive disorders: effects of increasing negative expiratory pressure.
BACKGROUND The negative expiratory pressure (NEP) technique is used to detect intrathoracic expiratory flow limitation (EFL) in patients with respiratory disorders. Application of NEP may result in a sustained decrease of flow below control as a result of upper airway collapse, which may invalidate interpretation of the test. This response to NEP is common in patients with obstructive sleep apn...
متن کاملExpiratory Flow Limitation in Intra and Extrathoracic Respiratory Disorders: Use of the Negative Expiratory Pressure Technique – Review and Recent Developments
Application of the NEP technique provides a simple, rapid, non-invasive, and reliable test to detect tidal expiratory flow limitation; b) it does not require a body-box or cooperation on the patient’s part; c) it can be applied in any posture, during mechanical ventilation, and during exercise; d) it provides new insights into the physiology and pathophysiology of sev‐ eral diseases and the sym...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 1984
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1984.tb06452.x