Uncemented porous-coated anatomic total hip replacement. Results at six years in a consecutive series

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of uncemented porous-coated anatomic total hip replacement.

We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed gi...

متن کامل

Clinical and roentgenographic evaluation of noncemented porous-coated anatomic medullary locking (AML) and porous-coated anatomic (PCA) total hip arthroplasties.

Eighty-four primary noncemented porous-coated total hip arthroplasties (THAs) in 78 patients were reviewed clinically and roentgenographically at an average follow-up period of 37 months. The average patient age was 51.9 years. Sixty-four Anatomic Medullary Locking (AML) devices were placed in 58 patients, and 20 Porous-Coated Anatomic (PCA) devices were placed in 20 patients. The AML devices h...

متن کامل

Long-term results of the cementless porous-coated anatomic total hip prosthesis.

Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration ...

متن کامل

The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement.

In a prospective study, 93 unselected consecutive uncemented hip arthroplasties were performed in 80 patients using the titanium-coated RM acetabular component and the CLS femoral component. The mean age of the patients at operation was 52 years (28 to 81). None were lost to follow-up. In the 23 patients who had died (26 hips) only one acetabular component had been revised. In the 57 living pat...

متن کامل

Mid-Term Clinical Results of VerSys Hip System (Zimmer) Uncemented Total Hip Replacement Arthroplasty.

Recent reports suggest that uncemented total hip replacement arthroplasty (THR) results in favorable short- to mid-term clinical results. In the present study, we assessed the mid-term clinical results of VerSys Hip System uncemented THR at our hospital. MATERIALS AND METHODS We studied patients who received THR using VerSys Hip System and who could be followed-up more than 3 years. Clinical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Bone and Joint Surgery. British volume

سال: 1993

ISSN: 0301-620X,2044-5377

DOI: 10.1302/0301-620x.75b1.8421036