Ultrasound detection using polymer microring optical resonator

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free-standing all-polymer microring resonator optical filter - Electronics Letters

Free-standing all-polymer microring resonator optical filters as prototypical elements in flexible integrated lightwave circuits are demonstrated. The fabrication and measurement methods are discussed. The measured spectrum shows good agreement with theoretical expectations. The crucial ‘critical’ coupling condition is achieved, resulting in a measurement limited 27 dB extinction of the filter ...

متن کامل

Low-noise wideband ultrasound detection using polymer microring resonators.

Polymer microring resonators for low-noise, wideband ultrasound detection are presented. Using a nanoimprinting technique, we fabricated polymer microring resonators with a quality factor of 6000 resulting in high sensitivity to ultrasound. A noise-equivalent pressure of 0.23 kPa over 1-75 MHz and a detection bandwidth of over 90 MHz at -3 dB were measured. These results demonstrate the potenti...

متن کامل

HCMT models of optical microring-resonator circuits

1 Ringresonator modelling Optical microresonator circuits [1, 2, 3] are considered, consisting of a number of not necessarily identical circular cavities and straight waveguides, with evanescent wave interaction between these elements. A simple configuration with a single cavity and two straight bus waveguides serves as an example to explain the frequency-domain Hybrid analytical/numerical Coup...

متن کامل

Optical microring resonator based corrosion sensing

Nanotechnology Laboratory, School of E Birmingham B15 2TT, UK. E-mail: h.butt@b Integrated Lightwave Research Group, De Engineering, University of Malaya, Kuala Lu Harvard Medical School and Wellman C General Hospital, 65 Landsdowne Street, Ca Harvard-MIT Division of Health Sciences an Technology, Cambridge, MA, 02139, USA † Electronic supplementary informa 10.1039/c6ra11538a Cite this: RSC Adv...

متن کامل

Biosensing Using Microring Resonator Interferograms

Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved using the silicon-wire propagation loss and coupling ratio from the MRR coupler. Our study showed th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Physics Letters

سال: 2004

ISSN: 0003-6951,1077-3118

DOI: 10.1063/1.1829775