Treatment Couch Modeling in the Treatment Planning System Eclipse
نویسندگان
چکیده
منابع مشابه
Treatment Couch Modeling in the Treatment Planning System Eclipse
The treatment couch and some of the positioning devices of patients receiving radiotherapy treatment are made of a material (carbon) which has low attenuation properties for the photon energies used in the radiotherapy. Previous investigations showed the suitability of carbon fiber tabletops in radiotherapy and their very low attenuation properties for a range of X-ray energies and field sizes ...
متن کاملVerification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet
Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...
متن کاملPlanning for mARC treatments with the Eclipse treatment planning system
While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of c...
متن کاملA treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
BACKGROUND The newest release of the Eclipse (Varian) treatment planning system (TPS) includes an optimizing engine for Elekta volumetric-modulated arc therapy (VMAT) planning. The purpose of this study was to evaluate this new algorithm and to compare it to intensity-modulated radiation therapy (IMRT) for various disease sites by creating single- and double-arc VMAT plans. METHODS A total of...
متن کاملModeling the Agility MLC in the Monaco treatment planning system
We investigate the relationship between the various parameters in the Monaco MLC model and dose calculation accuracy for an Elekta Agility MLC. The vendor-provided MLC modeling procedure - completed first with external vendor participation and then exclusively in-house - was used in combination with our own procedures to investigate several sets of MLC modeling parameters to determine their eff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cancer Science & Therapy
سال: 2010
ISSN: 1948-5956
DOI: 10.4172/1948-5956.1000049