Transformer Resonance: Reasons, Modeling Approaches, Solutions
نویسندگان
چکیده
Due to the extension of power grid with many complex and compact pieces equipment, transformers will be more exposed fast transient, resulting from various resonance conditions. Transformer can result in severe overvoltage on internal parts winding, leading insulation failure and, consequently, transformer outage. The main reasons for occurrence, practical method measure transformers, solution preventing resonances have been discussed scientific reports over past few decades; however, a comprehensive review these studies is not present literature. Hence this paper aims provide categorize resonance, modeling methods, appropriate solutions suppress phenomenon suggest some prospective protection future works.
منابع مشابه
Transformer Based Solutions to Power Quality Problems
In this paper we propose transformer-based solutions to several power quality problems. Elsewhere we have shown how to solve the acoustical noise emission problems. In this paper we introduce toroidal transformers with reduced inrush currents, transformers with reduced electromagnetic emissions, and other transformers useful to reduce the transfer of harmonics. With the low-inrush transformers ...
متن کاملModeling Reasons for Firms’ Growth
Static neoclassical framework cannot be applied to model time dependent processes or increasing returns to scale in production. The dynamization of the neoclassical theory of a firm by dynamic optimization, on the other hand, assumes inconsistent profit functions with the former. As a solution to these problems, we present a dynamic theory of a firm consistent with the static neoclassical theor...
متن کاملGeneral practitioners' low morale: reasons and solutions.
cognize this dilemma might encourage them to develop functional teams. Individual neurologists and geriatricians could continue to diagnose routine neurological problems referred to them. In addition, they could subspecialize so that each might have a specific input in a multidisciplinary team which focused, for example, on the diagnosis and continuing care of the big three: stroke, the epileps...
متن کاملPower Transformer Modeling for Inrush Current Calculation
The paper documents a new transformer model in ATPDraw called XFMR. This model handles 3-phase transformers with two or three windings. Autotransformers and all Wye and Delta couplings are supported. The model includes an inverse inductance matrix for the leakage description, optional frequency dependent winding resistance, capacitive coupling, and a topologically correct core model (3and 5-leg...
متن کاملTransformer Top-Oil Temperature Modeling and Simulation
The winding hot-spot temperature is one of the most critical parameters that affect the useful life of the power transformers. The winding hot-spot temperature can be calculated as function of the top-oil temperature that can estimated by using the ambient temperature and transformer loading measured data. This paper proposes the estimation of the top-oil temperature by using a method based on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2023
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2023.3284552