TRANS-AORTIC IMPLANTATION OF THE MEDTRONIC COREVALVE PROSTHESIS. SUCCESSFUL IMPLANTATION THROUGH AN ALTERNATIVE ACCESS ROUTE

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis.

AIMS Prosthesis-patient mismatch (P-PM) is an important determinant of morbidity and mortality following open aortic valve replacement. The aims of this study were to report its incidence and determinants following transcatheter aortic valve implantation (TAVI) with the Corevalve bioprosthesis, which have-thus far-not been described. METHODS AND RESULTS Patients with severe calcific aortic st...

متن کامل

Valve-in-valve implantation of Medtronic CoreValve prosthesis in patients with failing bioprosthetic aortic valves.

BACKGROUND Transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve (MCV) system might represent an alternative to conventional redo surgery in older high-risk patients with a failing aortic valve bioprosthesis. METHODS AND RESULTS Symptomatic patients with failing aortic valve bioprosthesis, aged ≥65 years with a logistic EuroSCORE ≥10 % were considered for treatment. Loc...

متن کامل

Left subclavian artery approach to CoreValve aortic prosthesis implantation.

1. Jauddi A, Fontana P, Mueller XM. Imaging of the abdominal aorta during examination of patients referres for transtoracic echocardiography. Schweiz Med Wochenschr. 1999;129:71-6. 2. Schwartz KV, Rashkow AM, Akella MS. Detection of abdominal aortic aneuriysm during routine echocardiography. Echocardiography. 1996;13:71-3. 3. Eisenberg MJ, Geraci SJ, Schiller NB. Screening for abdominal aortic ...

متن کامل

Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis

Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon ...

متن کامل

Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis.

OBJECTIVES The purpose of this study was to determine the predictors of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI). BACKGROUND TAVI has been associated with a high rate of paravalvular regurgitation, usually mild. Nevertheless, moderate to severe regurgitations still occur and may have negative clinical consequences. METHODS Fifty patients with severe aor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 2010

ISSN: 0735-1097

DOI: 10.1016/s0735-1097(10)62056-6