Tissue Density Mapping of Cone Beam CT Images for Accurate Dose Calculations
نویسندگان
چکیده
منابع مشابه
Tissue Density Mapping of Cone Beam CT Images for Accurate Dose Calculations
Purpose: To improve the accuracy in megavoltage photon beam dose calculation in CBCT-based radiation treatment (RT) plans, using a kilovoltage cone-beam computed tomography (CBCT)-todensity-step (CBCT-SF) function. Materials and Methods: The CBCT-SF table is constructed from differential histograms of the voxel values of CBCT and Fan-beam CT (FBCT). From the CBCT histograms, frequency peaks rep...
متن کاملShading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images
Cone-beam CT (CBCT) images are routinely acquired to verify patient position in radiotherapy (RT), but are typically not calibrated in Hounsfield Units (HU) and feature non-uniformity due to X-ray scatter and detector persistence effects. This prevents direct use of CBCT for re-calculation of RT delivered dose. We previously developed a prior-image based correction method to restore HU values a...
متن کاملHow Accurate Are the Fusion of Cone-Beam CT and 3-D Stereophotographic Images?
BACKGROUND Cone-beam Computed Tomography (CBCT) and stereophotography are two of the latest imaging modalities available for three-dimensional (3-D) visualization of craniofacial structures. However, CBCT provides only limited information on surface texture. This can be overcome by combining the bone images derived from CBCT with 3-D photographs. The objectives of this study were 1) to evaluate...
متن کاملReproducibility of facial soft tissue thicknesses for craniofacial reconstruction using cone-beam CT images.
The purpose of this study was to evaluate the reproducibility of the soft tissue (ST) thicknesses at 31 landmarks using the cone-beam computed tomography (CBCT) images obtained from 20 adult subjects. Four observers carried out ST thickness measurements using Skull Measure software, and the inter- and intra-observer error rates were evaluated. Only five of 31 landmarks showed significant differ...
متن کاملCone beam CT for dental and maxillofacial imaging: dose matters.
The widespread use of cone-beam CT (CBCT) in dentistry has led to increasing concern regarding justification and optimisation of CBCT exposures. When used as a substitute to multidetector CT (MDCT), CBCT can lead to significant dose reduction; however, low-dose protocols of current-generation MDCTs show that there is an overlap between CBCT and MDCT doses. More importantly, although the 3D info...