Time-Frequency Methods for Structural Health Monitoring
نویسندگان
چکیده
منابع مشابه
Time-Frequency Methods for Structural Health Monitoring †
Detection of early warning signals for the imminent failure of large and complex engineered structures is a daunting challenge with many open research questions. In this paper we report on novel ways to perform Structural Health Monitoring (SHM) of flood protection systems (levees, earthen dikes and concrete dams) using sensor data. We present a robust data-driven anomaly detection method that ...
متن کاملTime-frequency and time-scale analyses for structural health monitoring.
Signal processing is one of the most important elements of structural health monitoring. This paper documents applications of time-variant analysis for damage detection. Two main approaches, the time-frequency and the time-scale analyses are discussed. The discussion is illustrated by application examples relevant to damage detection.
متن کاملBayesian Methods for Aircraft Structural Health Monitoring
Aircraft structures, whether metallic or composite, are subject to service damage which requires their periodic inspection and maintenance. While taking the aircraft out of service is quite costly, the assurance of structural integrity requires such inspection – and possible repair work based on the inspection results obtained. If damage is detected from an inspection, the decision whether to r...
متن کاملLamb Waves Time-reversal Method using Frequency Tuning Technique for Structural Health Monitoring
Lamb wave time reversal method is a new and tempting baseline-free damage detection technique for structural health monitoring. With this method, certain types of damage can be detected without baseline data. However, the application of this method to thin-wall structures is complicated by the existence of at least two Lamb wave modes at any given frequency, and by the dispersion nature of the ...
متن کاملWireless Monitoring Techniques for Structural Health Monitoring
Recently, a variety of wireless structural health monitoring systems have been demonstrated as viable substitutes for traditional high-cost tethered monitoring systems. In this study, a prototype wireless sensing system is deployed on the Voigt Bridge (La Jolla, CA) and a historical theatre (Detroit, MI) to validate its performance against cabled monitoring systems. Acceleration time history re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2014
ISSN: 1424-8220
DOI: 10.3390/s140305147