Three-dimensional volumetry and fetal weight measurement
نویسندگان
چکیده
منابع مشابه
Measurement of fetal nuchal translucency thickness by three-dimensional ultrasound.
OBJECTIVE To investigate the feasibility and repeatability of nuchal translucency thickness measurement using three-dimensional ultrasound. METHODS Forty consecutive women with uncomplicated singleton pregnancies attending for Down syndrome screening at 11-14 weeks' gestation were included in this prospective crossover trial. Nuchal translucency thickness was measured using both two-dimension...
متن کاملThree-Dimensional Fetal Head
TERRY J. DUBOSE, MS, RDMS, The fetal head is three dimensional (3D). As 3D sonography becomes a clinical reality, there is a need to describe standard biometric parameters by which the head shape, proportions, and volumes may be measured and analyzed. This particular study presents measurements and methods that are applicable to newer 3D imaging systems. These measurements will provide consiste...
متن کاملComputer-assisted three-dimensional volumetry of the human pulmonary acini.
Computer-aided three-dimensional (3-D) volumetry of human pulmonary acini was undertaken using the left upper lobe of a 51-year-old female operated for small lung cancer. A normal part of this lobe, fixed by intrabronchial infusion with a mixture of polyethylene glycol and formalin, was subjected to serial sectioning, using a special slicer, into 48 serial slices of 0.5 mm in thickness. A soft ...
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملThree- and four-dimensional fetal echocardiography.
The rapid continuing development of 3-dimensional ultrasound imaging technologies has extended capabilities of fetal cardiac scanning beyond 2-dimensional imaging technologies and now provides a wide array of analytic possibilities. The acquisition of the 3D volume information is based on initial application of 2-dimensional imaging techniques including grey scale, Doppler, Power Doppler and B-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultrasound in Obstetrics and Gynecology
سال: 2007
ISSN: 0960-7692,1469-0705
DOI: 10.1002/uog.5181