THEORETICAL CONSIDERATION OF GAS VOID FRACTION AND FROTH HEIGHT ON A PERFORATED PLATE
نویسندگان
چکیده
منابع مشابه
ECT and LS-SVM Based Void Fraction Measurement of Oil-Gas Two-Phase Flow
A method based on Electrical Capacitance Tomography (ECT) and an improved Least Squares Support Vector Machine (LS-SVM) is proposed for void fraction measurement of oil-gas two-phase flow. In the modeling stage, to solve the two problems in LS-SVM, pruning skills are employed to make LS-SVM sparse and robust; then the Real-Coded Genetic Algorithm is introduced to solve the difficult problem...
متن کاملTheoretical and Experimental Studies of Upright Perforated Wave Filters
Liu et al. (1987) proposed a theoretical solution for scattering of waves through a permeable dissipation region. On the basis of bulk dissipation of the incident wave energy, this method is extended to evaluate the reflection and transmission coefficients of waves through a wave filter composed of rows of perforated sheets aligned normally to the direction of wave propagation. The results of t...
متن کاملect and ls-svm based void fraction measurement of oil-gas two-phase flow
a method based on electrical capacitance tomography (ect) and an improved least squares support vector machine (ls-svm) is proposed for void fraction measurement of oil-gas two-phase flow. in the modeling stage, to solve the two problems in ls-svm, pruning skills are employed to make ls-svm sparse and robust; then the real-coded genetic algorithm is introduced to solve the difficult problem of ...
متن کاملExperimental and Numerical Study of Perforated Steel Plate Shear Panels
Thin perforated Steel Plate Shear (SPS) Walls are among the most common types of energy dissipating systems. The applied holes reduce the shear strength of the plate and allow to decrease the profile size of the members at the boundary of the panel when these systems are used in the typical design of structures. On the other hand, the different fracture locations of these panels are visible whe...
متن کاملEffect of Perforated Plate Open Area on Gas Holdup in Rayon Fiber Suspensions
Three different aeration plates are used to study their effect on gas holdup and flow regime transition in fiber suspensions. The aeration plates differ by their open-area ratios (A=0.57%, 0.99%, and 2.14%), where the hole diameter remains the same while the number of holes increase. Experiments are performed using three different Rayon fiber lengths (L=3, 6, and 12mm) over a range of superfici...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
سال: 1973
ISSN: 0021-9592,1881-1299
DOI: 10.1252/jcej.6.38