The Validity and Reliability of 1-Hz and 5-Hz Global Positioning Systems for Linear, Multidirectional, and Soccer-Specific Activities

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The validity and reliability of 1-Hz and 5-Hz global positioning systems for linear, multidirectional, and soccer-specific activities.

PURPOSE The study aimed to analyze the validity and reliability of commercially available nondifferential Global Positioning System (NdGPS) devices for measures of total distance during linear, multidirectional and soccer-specific motion at 1-Hz and 5-Hz sampling frequencies. METHODS Linear (32 trials), multidirectional (192 trials) and soccer-specific courses (40 trials) were created to test...

متن کامل

Validity and Reliability of 5 Hz GPS for Measurement of Non- Linear Cycling Distance and Velocity

This study aimed to determine the validity and reliability of a 5 Hz GPS system for recording distance and velocity during non-linear cycling activity. One trained male cyclist (age 37 yrs; stature 172.4 cm; body mass 74.2 kg) took part in the study. Two non-differential GPS units (Minimax X3, Catapult) were attached securely into the rear pocket of a cycling shirt at approximately the T11-12 v...

متن کامل

The acceleration dependent validity and reliability of 10 Hz GPS.

OBJECTIVES To examine the validity and inter-unit reliability of 10 Hz GPS for measuring instantaneous velocity during maximal accelerations. DESIGN Experimental. METHODS Two 10 Hz GPS devices secured to a sliding platform mounted on a custom built monorail were towed whilst sprinting maximally over 10 m. Displacement of GPS devices was measured using a laser sampling at 2000 Hz, from which...

متن کامل

Validity and Reliability of 10-Hz Global Positioning System to Assess In-line Movement and Change of Direction

The objectives of the present study were to examine the validity and reliability of the 10 Hz Johan GPS unit in assessing in-line movement and change of direction. The validity was tested against the criterion measure of 200 m track-and-field (track-and-field athletes, n = 8) and 20 m shuttle run endurance test (female soccer players, n = 20). Intra-unit and inter-unit reliability was tested by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Sports Physiology and Performance

سال: 2010

ISSN: 1555-0265,1555-0273

DOI: 10.1123/ijspp.5.4.448