The Sutureless Aortic Valve Prosthesis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sutureless Prosthesis for Aortic Aneurysms

The device consists of four parts (Fig 1). The disposable mouthpiece (Inspiron No. 001200) fits into one end of a 6inch corrugated tube (Hudson Corr-A-Tube II, No. 1410). The other end of this tube is coupled to a connector (BardParker oxygen hose connector No. 5002) via a 22 X 22-mm adapter (Bard-Parker No. 5095). This connector fits snugly onto the male hub of the rubber tubing of most commer...

متن کامل

Sutureless aortic valve replacement.

The increasing incidence of aortic stenosis and greater co-morbidities and risk profiles of the contemporary patient population has driven the development of minimally invasive aortic valve surgery and percutaneous transcatheter aortic valve implantation (TAVI) techniques to reduce surgical trauma. Recent technological developments have led to an alternative minimally invasive option which avoi...

متن کامل

Valve-in-Valve Replacement Using a Sutureless Aortic Valve

BACKGROUND We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. CASE REPORT The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biop...

متن کامل

Aortic Root Enlargement or Sutureless Valve Implantation?

Aortic valve replacement (AVR) in patients with a small aortic annulus is a challenging issue. The importance of prosthesis-patient mismatch (PPM) post aortic valve replacement (AVR) is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively a...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of Surgery

سال: 1976

ISSN: 0003-4932

DOI: 10.1097/00000658-197608000-00007