The PILATUS 1M detector

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of an in-vacuum PILATUS 1M detector.

A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small-angle X-ray scattering (SAXS) expe...

متن کامل

Performance of single-photon-counting PILATUS detector modules

PILATUS is a silicon hybrid pixel detector system, operating in single-photon-counting mode, that has been developed at the Paul Scherrer Institut for the needs of macromolecular crystallography at the Swiss Light Source (SLS). A calibrated PILATUS module has been characterized with monochromatic synchrotron radiation. The influence of charge sharing on the count rate and the overall energy res...

متن کامل

PILATUS 2M A Detector for Small Angle X-ray Scattering

For the (coherent) small-angle X-ray scattering (SAXS) beamline X12SA of the Swiss Light Source at the Paul Scherrer Institut, a novel X-ray detector is built, the PILATUS 2M. Contributions in module fabrication, detector assembly, characterization and calibration are covered within the framework of this thesis. Furthermore, data analysis of a particular SAXS experiment demonstrating the perfor...

متن کامل

Radiation damage in room-temperature data acquisition with the PILATUS 6M pixel detector

The first study of room-temperature macromolecular crystallography data acquisition with a silicon pixel detector is presented, where the data are collected in continuous sample rotation mode, with millisecond read-out time and no read-out noise. Several successive datasets were collected sequentially from single test crystals of thaumatin and insulin. The dose rate ranged between ∼ 1320 Gy s(-...

متن کامل

Stress 1m!! Riemannian Metrics in Nonlinear Elasticity

U. Introduction In Doyle and Bricksen [1956. p. 77] it is observed that the Cauchy stress tensor 0 can be derived by varying the internal energy e with respect to the Riemannian metric on space: oab =Zpae/agab. Their formula has gone virtually unnoticed in the elasticity literature. In this lecture we shall explain some of the reasons why this formula is, in fact, of fundamental significance. S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Synchrotron Radiation

سال: 2006

ISSN: 0909-0495

DOI: 10.1107/s0909049505038665