The oil - paper insulation reliability estimation of 420 kV transformer concerning thermal stresses during exploitation conditions
نویسندگان
چکیده
منابع مشابه
Solid insulation drying of 110 kV paper-oil instrument transformers
Influence of moisture on the instrument transformers’ paper-oil insulation and its further maintenance is described in this paper. Improved insulation drying method using vacuum and temperature regulation with definite regulation algorithm of parameters is proposed and analyzed by comparing it with conventional drying method.
متن کاملdegradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses
در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...
15 صفحه اولReliability Evaluation Method for Oil–Paper Insulation in Power Transformers
The overall life of oil-immersed power transformers depends on the long-term life of the oil–paper insulation system throughout continuous operation. Studying the reliability assessment methods for oil–paper insulation can help determine the reliability level of power transformers accurately, and ensure their safe and stable operation. In the present paper, the life of oil–paper insulation is p...
متن کاملInvestigation on Thermal Aging of Ester from Palm Oil and Kraft Paper Composite Insulation System for High Voltage Transformer
Mineral oil is widely being used as insulation for high voltage equipments such as transformer due to its excellent dielectric properties. Recently, due to environment consideration and the long term availability, organic liquid insulations from plantations are being introduced. However, the performance of such insulations in composite with paper should be investigated in order to maintain the ...
متن کاملCanonical Correlation Between Partial Discharges and Gas Formation in Transformer Oil Paper Insulation
Dissolved gas analysis (DGA) has been widely applied to diagnose internal faults in transformer insulation systems. However, the accuracy of DGA technique is limited because of the lack of positive correlation of the fault-identifying gases with faults found in power transformers. This paper presents a laboratory study on the correlation between oil dissolved gas formation and partial discharge...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thermal Science
سال: 2016
ISSN: 0354-9836,2334-7163
DOI: 10.2298/tsci150409003a