The NA62 liquid Krypton calorimeter's new readout system
نویسندگان
چکیده
منابع مشابه
The Na62 Liquid Krypton Calorimeter Readout Module Published by Iop Publishing for Sissa the Na62 Liquid Krypton Calorimeter Readout Module Contents 1 Introduction 1 1.1 Na62 Detectors Layout 1 1.2 Na62 Trigger System 2
The NA62 experiment [1] at CERN SPS (Super Proton Synchrotron) accelerator will be focused on precision tests of the Standard Model via studies of ultra-rare decays of charged kaons. The high resolution Liquid Krypton (LKr) calorimeter of the former NA48 experiment [2], together with other detectors, will provide a photon-veto with hermetic coverage from zero out to large angles from the decay ...
متن کاملReadout Electronics of the Na62 Gigatracker System
A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...
متن کاملSingle crystalline LuAG fibers for homogeneous dual-readout calorimeters
For the next generation of calorimeters, designed to improve the energy resolution of hadrons and jets measurements, there is a need for highly granular detectors requiring peculiar geometries. Heavy inorganic scintillators allow compact homogeneous calorimeter designs with excellent energy resolution and dual-readout abilities. These scintillators are however not usually suited for geometries ...
متن کاملA digital Front-End Readout MIcrosystem for calorimeters at LHC
The Front-End Read-out MIcrosystem (FERMI) for calorimeters at LHC presented last year has been further developed with the aim to achieve a fu l l silicon implementation early 1994. Each microsystem will, as before, contain 9 channels with 15-16 bits dynamic range using IO-bit AD converters sampled every 15 ns. The function is accomplished by using a non-linear amplifier in front of the ADC to ...
متن کاملNatrium : Use of FPGA embedded processors for real - time data compression
We present test results and characterization of a data compression system for the readout of the NA62 liquid krypton calorimeter trigger processor. The Level-0 electromagnetic calorimeter trigger processor of the NA62 experiment at CERN receives digitized data from the calorimeter main readout board. These data are stored on an on-board DDR2 RAM memory and read out upon reception of a Level-0 a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2014
ISSN: 1748-0221
DOI: 10.1088/1748-0221/9/01/c01047