The measurement of ultrasonographic optic nerve sheath diameter in patients with hyperglycemia
نویسندگان
چکیده
منابع مشابه
Ultrasonographic optic nerve sheath diameter measurement in overweight parturient with intracranial tumour: Guiding choice of anaesthesia
A 26‐year‐old 36‐week primigravida with body mass index of 28.33 with intracranial space occupying lesion was planned for elective caesarean section. The patient was having frontal headache for past 1 month with left eye ptosis for last 3 weeks. Headache was associated with vomiting. There was no history of seizures. Magnetic resonance imaging (MRI) obtained 3 weeks before showed large lobulate...
متن کاملAssessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement
BACKGROUND Ultrasonograpic retrobulbar optic nerve sheath diameter (ONSD) measurement is considered to be an alternative noninvasive method to estimate intracranial pressure,but the further validation is urgently needed. The aim of the current study was to investigate the association of the ultrasonographic ONSD and intracranial pressure (ICP) in patients. METHODS One hundred and ten patients...
متن کاملUltrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
BACKGROUND Measurement of optic nerve sheath diameter (ONSD) is a fast and non-invasive method in detecting elevated intracranial pressure. However, the reported normal range of ONSD was inconsistent. The objective of the study was to determine the normal range of ONSD in healthy Chinese adults. METHODS Eyeball transverse diameter (ETD), optic nerve diameter (OND), and ONSD were measured by u...
متن کاملNoninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
We aimed to quantitatively assess intracranial pressure (ICP) using optic nerve sheath diameter (ONSD) measurements. We recruited 316 neurology patients in whom ultrasonographic ONSD was measured before lumbar puncture. They were randomly divided into a modeling and a test group at a ratio of 7:3. In the modeling group, we conducted univariate and multivariate analyses to assess associations be...
متن کاملCoronal Axis Measurement of the Optic Nerve Sheath Diameter.
OBJECTIVES The true optic nerve sheath diameter cutoff value for detecting elevated intracranial pressure is variable. The variability may stem from the technique used to acquire sonographic measurements of the optic nerve sheath diameter as well as sonographic artifacts inherent to the technique. The purpose of this study was to compare the traditional visual axis technique to an infraorbital ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Hong Kong Journal of Emergency Medicine
سال: 2019
ISSN: 1024-9079,2309-5407
DOI: 10.1177/1024907919892161