The Majorana Demonstrator readout electronics system

نویسندگان

چکیده

Abstract The Majorana Demonstrator comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed have low electronic noise, radioactive backgrounds minimized by using low-mass components low-radioactivity materials near detectors. This paper provides a description all electronics, spanning front-end internal cabling, back-end digitizer, power supplies, along with grounding scheme. spectroscopic performance achieved these is also demonstrated.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Readout Electronics of the Na62 Gigatracker System

A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...

متن کامل

Gallium Arsenide - Based Readout Electronics

The readout of detector arrays requires the monolithic or hybrid integration of a integrate circuit multiplexer with the detector array. In most LWIR and VLWIR applications, a hybrid approach is used. For example, the detector array may be built from HgCdTe and the readout integrated circuit may be silicon CMOS [1]. The two integrated circuits are mated through a bump-bonding process in which e...

متن کامل

The EMBRACE System Demonstrator

Within the EMBRACE project an advanced communications system and network was developed. It uses the DVB technology for the high-speed downlink and a novel multi-frequency TDMA system for the return link. The return link is scaleable to accommodate the variety of data rates. Emphasis was put on providing quality of service (QoS) in wireless IP networks. Site diversity is used to increase the ava...

متن کامل

CMS Calorimeter Trigger/Readout Electronics for SLHC

The SLHC will be a very challenging environment for physics and for the trigger and DAQ in particular. Expected pileup multiplicies on the level of 40-200 interactions every beam crossing will flood the detector with the “ambient noise” of many low pT particles. The impact of these low pT particles is particular large for the hadron calorimeter, which has a relatively large cell size (compared ...

متن کامل

The Whole System Demonstrator Programme

Stanton P Newman (principal investigator City University London), Martin Bardsley (The Nuffield Trust), James Barlow (Imperial College London), Jennifer Beecham (London School of Economics), Michelle Beynon (City University London/University College London), John Billings (The Nuffield Trust), Andy Bowen (University of Manchester), Pete Bower (University of Manchester), Martin Cartwright (City ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2022

ISSN: ['1748-0221']

DOI: https://doi.org/10.1088/1748-0221/17/05/t05003