The influence of beam delivery uncertainty on dose uniformity and penumbra for pencil beam scanning in carbon-ion radiotherapy
نویسندگان
چکیده
منابع مشابه
Carbon-ion pencil beam scanning for thoracic treatment – initiation report and dose metrics evaluation
Carbon-ion beam scanning has not previously been used for moving tumor treatments. We have commenced respiratory-gated carbon-ion radiotherapy (CIRT) in the thoracic and abdominal regions under free-breathing conditions as a clinical trial. This study aimed to investigate this treatment in the lungs in comparison with passive scattering CIRT. Five patients had thoracic tumors treated with carbo...
متن کاملGolden beam data for proton pencil-beam scanning.
Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...
متن کاملAlgorithms for Biological Dose Optimization in Ion Beam Radiotherapy
From 1997 until 2008 about 440 cancer patients were successfully treated in the ion therapy project at GSI. The patient treatment planning was performed with the software TRiP [1, 2]. A crucial part of the treatment planning is the particle number optimization with the goal to achieve a target dose distribution as close as possible to the prescribed biological dose distribution. The optimizatio...
متن کاملIntrafractional dose variation and beam configuration in carbon ion radiotherapy for esophageal cancer
BACKGROUND In carbon ion radiotherapy (CIR) for esophageal cancer, organ and target motion is a major challenge for treatment planning due to potential range deviations. This study intends to analyze the impact of intrafractional variations on dosimetric parameters and to identify favourable settings for robust treatment plans. METHODS We contoured esophageal boost volumes in different organ ...
متن کاملDevelopment of Optical Fiber Based Measurement System for the Verification of Entrance Dose Map in Pencil Beam Scanning Proton Beam
This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam moni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLOS ONE
سال: 2021
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0249452