The Heart Rate Monitoring System using Inverted Photoplethysmography

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using photoplethysmography in heart rate monitoring of patients with epilepsy.

Heart rate is a useful neurophysiological sign when monitoring seizures in patients with epilepsy. In an ambulatory setting, heart rate is measured with ECG involving electrodes on the skin. This method is uncomfortable which is burdensome for patients and is sensitive to motion artifacts, which decrease the usability of measurements. In this study, green light photoplethysmography, an optical ...

متن کامل

Independent Component Analysis for Fetal Heart Rate Detection Using Photoplethysmography

Photoplethysmography (PPG) is an optoelectronic technique for measuring and recording changes in the volume of body parts. These changes are associated with each heart beat and acquired by pulse oximetry. Fetal heart rate (FHR) monitoring using PPG is a challenging task since the acquired signals present the pattern of both fetal and maternal hearts. The effect of maternal component, noise and ...

متن کامل

Lightweight wrist photoplethysmography for heavy exercise: motion robust heart rate monitoring algorithm

The challenge of heart rate monitoring based on wrist photoplethysmography (PPG) during heavy exercise is addressed. PPG is susceptible to motion artefacts, which have to be mitigated for accurate heart rate estimation. Motion artefacts are particularly apparent for wrist devices, for example, a smart watch, because of the high mobility of the arms. Proposed is a low complexity highly accurate ...

متن کامل

Digital Heart Rate Variability Monitoring System

In this paper we describe the implementation of an application specific integrated chip (ASIC) for digital heart rate variability monitoring system. The proposed system extracts the R peaks from the input ECG signals using peak detection algorithm and stores the computed R-R intervals into an efficient SRAM as the internal memory. A histogram sorter sorts the R-R intervals which are then indexe...

متن کامل

Embedded Prototype System for Monitoring Heart Rate

The vital signs monitoring is very important for patients that suffers some chronic disease because they reflect basic and essential functions in the body. In Mexico, in the last few years, we have noticed that the mortality rate in patients with heart disease has increased significantly due to late diagnosis and lack medical care to patients who have been diagnosed. This work presents a propos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Korea Society of Computer and Information

سال: 2012

ISSN: 1598-849X

DOI: 10.9708/jksci.2012.17.3.105