The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams
نویسندگان
چکیده
منابع مشابه
Development of CT Scanner Models for Patient Organ Dose Calculations Using Monte Carlo Methods
There is a serious and growing concern about the CT dose delivered by diagnostic CT examinations or image-guided radiation therapy imaging procedures. To better understand and to accurately quantify radiation dose due to CT imaging, Monte Carlo based CT scanner models are needed. This dissertation describes the development, validation, and application of detailed CT scanner models including a G...
متن کاملSize specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT
Objective(s): Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE...
متن کاملImpact of ICRP-89 Based Models on Dose Estimates for Radiopharmaceuticals and CT Exams
New mathematical phantoms based on medical image data are allowing evaluation of internal and external dose calculations using better anatomic realism and inclusion of organs that were not previously defined. In this work, we show preliminary data for new radiation dose estimates for radiopharmaceuticals and CT examinations, using Monte Carlo radiation simulation routines developed in the Geant...
متن کاملinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...