The evaluation of actual fire resistance limits of steel structures exposed to real fire loading

نویسندگان

چکیده

Introduction . The fire resistance limits of load-bearing and enclosing structures can be identified using the method heat-and-mass transfer calculation in case fire. multifactorial nature nonlinearity problem makes application this complicated. If necessary, temperature regime, demonstrating conditions real fire, applied. In work, actual metal a thermal power station are calculated.Goals objectives. co-authors attempt to identify bearing most dangerous development scenario. Methods Taking into account complexity space-planning solutions building, field-focused was selected. This is applicable premises, featuring complex geometric shape, where one dimension much larger than others. Non-stationary three-dimensional differential equations mass, momentum energy conservation solved for gas medium inside room (the Reynolds type Navier–Stokes equations), as well components optical density smoke. A heat equation determine distribution building structure one-dimensional case. limit moment time following start when in, at least, point reaches critical value. Results discussion Calculation results show that scenario, within 15 minutes maximum temperatures far below 500 °C. Conclusions Load-bearing an engine room, has steam turbines, don’t need protection.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stainless steel structures in fire

The initial material cost of structural stainless steel is about four times that of structural carbon steel, due largely to the expense of the alloying elements and the relatively low volume of production. Given broadly similar structural performance, additional areas of benefit need to be identified and exploited in order to establish stainless steel as a viable alternative material for constr...

متن کامل

The Current Situation and Development of Fire Resistance Design for Steel Structures in China

A review of the current situation and development of fire safety design for steel structures in China is given in this paper. Several codes and specifications used for fire safety design in China are introduced, and the present design methods are summarized. Then some research achievements on the behavior of steel structures at elevated temperature are presented. The achievements include materi...

متن کامل

Computation of Structural Fire Resistance of Steel Sections

The main object of this study is to compute the structural fire resistance for several steel members under different loading conditions. This is done in chapter 4 using two advanced calculation models. Chapter 1 contains prescriptions according to European codes, needed for this research. In Chapter 2 the notion of structural fire resistance is explained and also information about the types of ...

متن کامل

Fire fighters exposed to electrical hazards during wildland fire operations.

DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention National Institute for Occupational Safety and Health Among the various hazards fire fighters face are electrical hazards during wildland fire suppression activities. The National Fire Protection Association (NFPA) reports that 10 fire fighters died from contact with electricity during wildland fires between 1980...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ????????????????????????

سال: 2022

ISSN: ['0869-7493', '2587-6201']

DOI: https://doi.org/10.22227/0869-7493.2021.30.06.61-72