TG-69: radiographic film for megavoltage beam dosimetry.
TG-69 is a task group report of the AAPM on the use of radiographic film for dosimetry. Radiographic films have been used for radiation dosimetry since the discovery of x-rays and have become an integral part of dose verification for both routine quality assurance and for complex treatments such as soft wedges (dynamic and virtual), intensity modulated radiation therapy (IMRT), image guided rad...
متن کاملInvestigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3 x 3 cm2 to 25 x 25 cm2) and depths (d(max) to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric r...
متن کاملRadiographic film dosimetry of proton beams for depth‐dose constancy check and beam profile measurement
Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (rat...
متن کاملEvaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry
The purpose of this study was to quantify the performance and assess the utility of two different types of scanners for radiochromic EBT film dosimetry: a commercial flatbed document scanner and a widely used radiographic film scanner. We evaluated the Epson Perfection V700 Photo flatbed scanner and the Vidar VXR Dosimetry Pro Advantage scanner as measurement devices for radiochromic EBT film. ...
متن کاملSource and detector polarization effects on radiographic film dosimetry.
Kodak X-Omat V radiographic film has been tested for its polarization properties when using polarized and non-polarized light sources and detectors. The radiographic film has been shown to produce a relatively small but not negligible (less than 5%) variation in 90 degrees cycles in measured optical density within the visible spectrum when the light source is fully linear polarized and the film...