TCT-494 Very long-term (8-year) angiographic and clinical outcomes after biodegradable polymer-based biolimus-eluting stent implantation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction.

OBJECTIVE To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS The LEADERS trial is a multicentre all-comer study, where patients (n=170...

متن کامل

Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents

There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 pat...

متن کامل

Stent Fracture After Sirolimus-Eluting Stent Implantation: 8-Year Clinical Outcomes.

BACKGROUND Stent fracture (SF) after sirolimus-eluting stent implantation is reported to be associated with target lesion revascularization (TLR) and stent thrombosis. We aimed to assess the clinical impact of SF at 8 years. METHODS AND RESULTS Between 2002 and 2005, 972 patients (1795 lesions) underwent sirolimus-eluting stent implantation and follow-up angiography within 1 year after index ...

متن کامل

Comparison of long-term angiographic follow-up after sirolimus-eluting stent and bare-metal stent implantation.

BACKGROUND The sirolimus-eluting stent (SES) has dramatically reduced the rate of restenosis in comparison to that with the bare-metal stent (BMS). In previous studies, the minimal luminal diameter (MLD) of lesions treated with a BMS was shown to improve from 6 months to 1 year. METHODS To evaluate 6-month and 1-year outcomes, angiographic follow-up data were analyzed for 285 patients (451 le...

متن کامل

Long-term (8 year) outcomes and predictors of major adverse cardiac events after full metal jacket drug-eluting stent implantation.

OBJECTIVES We examined long-term outcomes and predictors of major adverse cardiac events after the full metal jacket (FMJ) stent implantation. BACKGROUND The FMJ procedure has been used to treat diffuse coronary artery disease (CAD), but long-term outcomes remain unknown. METHODS The study population consisted of 347 consecutive patients (352 lesions) who had been treated for de novo diffus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 2016

ISSN: 0735-1097

DOI: 10.1016/j.jacc.2016.09.630