Tailored-waveform collisional activation of peptide ion electron transfer survivor ions in cation transmission mode ion/ion reaction experiments

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-energy collisional activation studied via angle-resolved translational energy spectra of survivor ions.

Angle-resolved translational energy spectroscopy has been applied to Cs4I + (3) ions that survived 8 keV collisions with a range of collision gas targets, including inert gases and deuterium. The experimental data comprise values of the translational energy loss ΔTR as a function of the (laboratory-frame) scattering angle θ R for each collision gas under conditions such that single-collision ev...

متن کامل

Ion-neutral collisional cross sections of carbohydrate isomers as divalent cation adducts and their electron transfer products.

As the gravity of glycoscience continues to amass, a commensurate demand for rapid, sensitive, and structurally comprehensive glycoanalytical tools has arisen. Among the most elusive but desirable analytical capabilities is the ability to expeditiously and unambiguously detect, distinguish, and resolve carbohydrates that differ only in their constitutional isomerism and/or stereoisomerism. Whil...

متن کامل

The mechanisms of collisional activation of ions in mass spectrometry.

This article is a review of the mechanisms responsible for collisional activation of ions in mass spectrometers. Part I gives a general introduction to the processes occurring when a projectile ion and neutral target collide. The theoretical background to the physical phenomena of curve-crossing excitation (for electronic and vibrational excitation), impulsive collisions (for direct translation...

متن کامل

Ion mobility-mass spectrometer interface for collisional activation of mobility separated ions.

An ion mobility-mass spectrometer (IM-MS) interface is described that can be employed to perform collisional activation and/or collision-induced dissociation (CID) with good transmission of mobility separated ions to the MS analyzer. The IM-MS interface consists of a stacked-ring ion guide design, where the field strength and pressure ratio can be operated such that structural rearrangement rea...

متن کامل

SO2-* electron transfer ion/ion reactions with disulfide linked polypeptide ions.

Multiply-charged peptide cations comprised of two polypeptide chains (designated A and B) bound via a disulfide linkage have been reacted with SO2-* in an electrodynamic ion trap mass spectrometer. These reactions proceed through both proton transfer (without dissociation) and electron transfer (with and without dissociation). Electron transfer reactions are shown to give rise to cleavage along...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Analyst

سال: 2009

ISSN: 0003-2654,1364-5528

DOI: 10.1039/b821348h