Synthetic fibre reinforcement in concrete tramlines
نویسندگان
چکیده
منابع مشابه
Glass Fibre Reinforced Concrete
Glass Fibre Reinforced Concrete is recent introduction in the field of concrete technology. The present day world is witnessing the construction of very challenging and difficult Civil Engineering Structures. Concrete being the most important and widely used material is called upon to possess very high strength and sufficient workability properties. Concrete the most widely used consrtuction ma...
متن کاملDistributed optical fibre sensing in synthetic fibre ropes and cables
Distributed strain measurements on synthetic fibre ropes as used in marine applications are reported. The ropes incorporate single mode fibre-optic sensors for strain measurement. A Brillouin-amplification-based distributed strain measuring system has been utilised to interrogate the fibre sensors incorporated into a parallel yarn aramid rope. Initial results are presented to conclusively demon...
متن کاملKnee degeneration in concrete reinforcement workers.
The loads on the knees in concrete reinforcement work and maintenance painting were analysed on eight construction work sites. A total of 352 reinforcement workers and 231 painters. Finnish men aged 20-64, were clinically and radiologically examined to determine the condition of the knee joints in active workers. The loads on the knees and the occurrence of minor injuries and accidents were hig...
متن کاملBond of reinforcement in polymer concrete
Polymer concrete, a composite material in which the binding material is some type of polymer, is being used more widely in the construction industry. Polymer concretes can also contain steel reinforcing rebars; therefore, the rate of adhesion between polymer concrete and reinforcing steel must be determined. Our study investigated the extent and behaviour of adhesion in the case of reinforcing ...
متن کاملBond of Reinforcement in High-Strength Concrete
This paper describes an examination of the development of tension lap splices in high-strength concrete and the applicability of the restriction in the ACI 318 code where the values of √fc′ used to calculate development length shall not exceed 100 psi. The focus is on the development of splices with Grade 60 epoxy-coated and uncoated bars in normalweight concrete. A summary of the behavior of b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Concrete Structures
سال: 2018
ISSN: 2062-7904
DOI: 10.32970/cs.2018.1.1