Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging
نویسندگان
چکیده
منابع مشابه
Supercontinuum stimulated emission depletion fluorescence lifetime imaging.
Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The ...
متن کاملUltrahigh-contrast imaging by temporally modulated stimulated emission depletion.
Stimulated emission depletion (STED) is the key optical technology enabling super-resolution microscopy below the diffraction limit. Here, we demonstrate that modulation of STED in the time domain, combined with properly designed lock-in detection, can radically enhance the contrast of fluorescent images of strongly autofluorescent biotissues. In our experiments, the temporally modulated STED t...
متن کاملTomographic fluorescence lifetime imaging
Fluorescence lifetime imaging microscopy (FLIM) is a well-established technique (Bastiaens and Squire 1999; Berezovska et al. 2003; Selvin 2000; Vogel et al. 2006) that combines microscopic techniques with time-resolved detection to provide high-resolution lifetime images of thin tissue sections. This chapter concerns the in vivo time domain imaging of fluorescent contrast agents embedded in de...
متن کاملFluorescence lifetime imaging ophthalmoscopy
Imaging techniques based on retinal autofluorescence have found broad applications in ophthalmology because they are extremely sensitive and noninvasive. Conventional fundus autofluorescence imaging measures fluorescence intensity of endogenous retinal fluorophores. It mainly derives its signal from lipofuscin at the level of the retinal pigment epithelium. Fundus autofluorescence, however, can...
متن کاملStroboscopic fluorescence lifetime imaging.
We report a fluorescence lifetime imaging technique that uses the time integrated response to a periodic optical excitation, eliminating the need for time resolution in detection. A Dirac pulse train of variable period is used to probe the frequency response of the total fluorescence per pulse leading to a frequency roll-off that is dependent on the relaxation rate of the fluorophores. The tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Physical Chemistry B
سال: 2012
ISSN: 1520-6106,1520-5207
DOI: 10.1021/jp303912p