Successive analysis of chloride ion and hypochlorous acid by direct potentiometry with chloride ion-selective electrode
نویسندگان
چکیده
منابع مشابه
Bicarbonate interference with chloride-ion-selective electrodes.
echocardiography. All attending phy-sicians/cardiologists were blinded to the BNP results. To determine the diagnostic accuracy of the two assays for CHF, we performed ROC plot analysis, and areas under the curve (AUC) were calculated for both BNP assays. Comparisons between AUC were assessed according to the method of Hanley and McNeil (10). Cutoff values for the two methods were determined at...
متن کاملReliability of IL Monarch ion-selective electrode module for sodium, potassium, and chloride measurements.
We evaluated the IL Monarch random-access centrifugal analyzer for measurement of Na+, K+, and Cl- by an indirect potentiometric method. For different concentrations of control material, the total precision (CV) ranged between 0.82% and 1.14% for the three electrolytes; linearity was acceptable within a range of 103 to 215 mmol/L for Na+, 1.6-15.25 mmol/L for K+, and 80-173 mmol/L for Cl-. Data...
متن کاملEarly detection of the selectivity loss of the Cobas Integra analyzer chloride ion-selective electrode.
accordance with the current revision of the Helsinki Declaration. The detection limit for the assay was 0.006 g/L. In the linearity studies , the hypothesis of a linear fit was accepted for all examined samples (P Ͼ0.11), and r values were Ͼ0.9989 for dilution with a negative serum pool and Ͼ0.9978 for dilution with buffer. All mean recoveries were within Ϯ 10% of the native concentrations. Th...
متن کاملDetermination of Perchlorate Ion With Tetraphenylarsonium Chloride
A detailed study of precipitation reaction of perchlorate ion with tetraphenylarsonium chloride is reported. Optimum conditions for quantitative precipitation of perchlorate ion were determined. A gravimetric and a spectrophotometric method for perchlorate ion are proposed. The spectrophotometric method is based upon dissolution of ( C.H.),AsClO. in acetonitrile and subsequent measurement of ab...
متن کاملHydrogen ion-selective poly(vinyl chloride) membrane electrode based on a calix[4]arene.
A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...