Sub-millimeter T2 weighted fMRI at 7 T: comparison of 3D-GRASE and 2D SE-EPI
نویسندگان
چکیده
منابع مشابه
Sub-millimeter T2 weighted fMRI at 7 T: comparison of 3D-GRASE and 2D SE-EPI
Functional magnetic resonance imaging (fMRI) allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD) contrast employing T(*) 2 weighted 2D multi-slice echo-planar imaging (EPI). At ultra-high magnetic field (i.e., 7 T and above), it has been shown experimentally a...
متن کاملAnatomical imaging at 7 T using 2D GRASE – A Comparison with 2D TSE
Introduction: GRASE (Gradient-and Spin-Echo) [1] imaging has recently been used successfully for perfusion measurements [2] and functional MRI [3]. However, due to known blurring and ringing artifacts [4] GRASE still awaits a breakthrough in structural imaging [5-7]. At high field strengths such as 7 T, many imaging sequences are limited in their spatial coverage per unit time, due to their hig...
متن کاملT2-weighted BOLD fMRI at 9.4 T using a S2-SSFP-EPI sequence
Introduction: It has been hypothesized that T2-weighted BOLD fMRI at ultra-high field shows higher spatial specificity than T2*weighted BOLD, since the main signal contribution is expected to come from the extravascular spins of the microvasculature [1-3]. Unfortunately, the number of slices that can be acquired in multi-slice SE-EPI is often highly limited at ultra-high field due to SAR constr...
متن کاملComparison of single-shot 2D EPI and segmented 3D EVI acquisition for fMRI at 7T
Introduction Echo volumar imaging (EVI) has been demonstrated to be an attractive tool for high spatiotemporal fMRI. Compared to 2D single shot acquisitions, EVI benefits from increased SNR due to the volume excitation. At the same time, however, increased signal fluctuations (physiological noise) have been observed in segmented 3D spiral fMRI investigations, which counteract the SNR gain of th...
متن کاملComparison of 3D FLAIR, 2D FLAIR, and 2D T2-weighted MR imaging of brain stem anatomy.
BACKGROUND AND PURPOSE Although 3D FLAIR imaging visualizes detailed structures of the brain stem, it has not been used to evaluate its normal anatomy. The purpose of this study was to evaluate whether 3D FLAIR images can provide more detailed anatomic information of the brain stem than 2D FLAIR and 2D T2WI. MATERIALS AND METHODS We prospectively evaluated MR images in 10 healthy volunteers. ...