Study of Thermometric Titration Using Differential Thermistor

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

متن کامل

an exploratory study of differential item functioning (dif) in efl reading comprehension

بررسی دلایل عملکرد متفاوت سوالات آزمون درک مطلب به زبان خارجی تاریخچه ی تحقیق درباره ی منابع عملکرد مختلف سوالات (دیف) در آزمون درک مطلب پر است از مجموعه ای از متغیرهای فرضیه ای که چند مورد از مهمترین آنها عبارتند از: جنسیت، آشنایی با موضوع متن، علاقه به موضوع یا محتوای متن، حدس زدن، و عوامل بافت اجتماعی (پی 2004؛ زومبو و گلین 2005). مطالعه حاضر با استناد به فلسفه ی انکارپذیری پوپر عوامل ذکر...

15 صفحه اول

Fast detection of atrazine in corn using thermometric biosensors.

Fast detection is important in screening large-scale samples. This study establishes a direct competitive ELISA method (dcTELISA) based on an enzyme thermistor for fast atrazine (ATZ) detection. ATZ competes with β-lactamase-labeled ATZ (ATZ-E) for the binding sites on anti-ATZ monoclonal antibody (mAb). The mAb are covalently bound to Controlled Pore Glass (CPG) in an immunoreactor to form imm...

متن کامل

Fast thermistor string (NIOZ)

Fast thermistor string observations at the slope of Great Meteor Seamount H. van Haren, R. Groenewegen, M. Laan, and B. Koster Royal Netherlands Institute for Sea Research (NIOZ), P.O. Box 59, 1790 AB Den Burg, The Netherlands Received: 15 November 2004 – Accepted: 14 December 2004 – Published: 22 December 2004 Correspondence to: H. van Haren ([email protected]) © 2004 Author(s). This work is lice...

متن کامل

A Study of Thermistor Performance within a Textile Structure

Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of the Society of Chemical Industry, Japan

سال: 1969

ISSN: 0023-2734,2185-0860

DOI: 10.1246/nikkashi1898.72.6_1263