Structural investigations on microcrystals with a highly collimated synchrotron beam
نویسندگان
چکیده
منابع مشابه
Creating a collimated ultrasound beam in highly attenuating fluids.
We have devised a method, based on a parametric array concept, to create a low-frequency (300-500 kHz) collimated ultrasound beam in fluids highly attenuating to sound. This collimated beam serves as the basis for designing an ultrasound visualization system that can be used in the oil exploration industry for down-hole imaging in drilling fluids. We present the results of two different approac...
متن کاملSerial crystallography on in vivo grown microcrystals using synchrotron radiation
Crystal structure determinations of biological macromolecules are limited by the availability of sufficiently sized crystals and by the fact that crystal quality deteriorates during data collection owing to radiation damage. Exploiting a micrometre-sized X-ray beam, high-precision diffractometry and shutterless data acquisition with a pixel-array detector, a strategy for collecting data from ma...
متن کاملTitle Afterglow emission from highly collimated jets with flat electron
We derive light curves of the afterglow emission from highly collimated jets if the power-law index (p) of the electron energy distribution is above 1 but below 2. We find the following: (1) Below the characteristic synchrotron frequency, the light-curve index depends generally on p. (2) As long as the jet expansion is spherical, the light-curve index above the characteristic frequency increase...
متن کاملProtein crystallography with a micrometre-sized synchrotron-radiation beam
For the first time, protein microcrystallography has been performed with a focused synchrotron-radiation beam of 1 microm using a goniometer with a sub-micrometre sphere of confusion. The crystal structure of xylanase II has been determined with a flux density of about 3 x 10(10) photons s(-1) microm(-2) at the sample. Two sets of diffraction images collected from different sized crystals were ...
متن کاملA highly-collimated SiO jet in the HH212 protostellar outflow
We mapped the inner 40 ′′ of the HH212 Class 0 outflow in SiO(2–1), SiO(5–4) and continuum using the Plateau de Bure interferometer in its extended configurations. The unprecedented angular resolution (down to 0. 34) allows accurate comparison with a new, deep H2 image obtained at the VLT. The SiO emission is confined to a highly-collimated bipolar jet (width ∼ 0. 35) along the outflow axis. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica Section A Foundations of Crystallography
سال: 1996
ISSN: 0108-7673
DOI: 10.1107/s0108767396098078