Stochastic modelling of 3D fiber structures imaged with X-ray microtomography
نویسندگان
چکیده
• A parametric stochastic fiber model for generating virtual structures is presented. sample fibrous material imaged using X-ray microtomography. Statistical information from the used to determine parameters. Several relevant measures are show consistency between structures. Many products incorporate into their design with particular levels of permeability as a way control retention and flow liquid. The production experimental testing these materials can be expensive time consuming, particularly if it needs optimised desired level absorbency. We consider replacement real facilitate studying relationship structure properties in cheaper more convenient manner. 3D image data sets obtained microtomography individual fibers isolated. segmented estimate parameters softcore use several spatial structures, demonstrate lattice Boltzmann simulations that our has good agreement respect physical material.
منابع مشابه
X-ray microtomography of materials
shapes. destructively and with spatial resolution which can approach that of optical microscopy (typically, no After presenting the author’s perspective of the better than 1 mm in samples whose cross-sectional development of microtomography, imaging, X-ray diameter is on the order of 1 mm, and 10 mm for attenuation, and the physical concepts underlying 10 mm specimens). First, X-ray computed to...
متن کاملX-ray microtomography in biology.
Progress in high-resolution X-ray microtomography has provided us with a practical approach to determining three-dimensional (3D) structures of opaque samples at micrometer to submicrometer resolution. In this review, we give an introduction to hard X-ray microtomography and its application to the visualization of 3D structures of biological soft tissues. Practical aspects of sample preparation...
متن کاملX-ray computed microtomography of sea ice
Introduction Conclusions References Tables Figures
متن کاملX-ray microtomography of bones and teeth.
X-ray microtomography is a miniaturized version of computerized axial tomography with a resolution of the order of micrometres. In the biomedical field it is particularly useful in the study of hard tissue because of its ability to accurately measure the linear attenuation coefficient. From this, the mineral concentration can be computed, which is one measure of bone quality. Using microtomogra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Computational Materials Science
سال: 2021
ISSN: ['1879-0801', '0927-0256']
DOI: https://doi.org/10.1016/j.commatsci.2021.110433