Steam temperature stability in a direct steam generation solar power plant
نویسندگان
چکیده
منابع مشابه
Linear Identification of a Steam Generation Plant
The paper examines the development of models of steam generation plant using linear identification techniques. The identification process is carried out using experimental data of a multi-input multi-output MIMO system representation. Various techniques of modeling and identification are applied considering the complete system as a MIMO model and studying the effect of all the inputs on individ...
متن کاملBuffer storage for direct steam generation
Fast reaction times and high discharge rates make steam accumulators a promising option for compensation of fast transients in insolation for solarthermal systems using steam as working medium. Using the volume of components like separator drums or heat exchangers for storage of pressurized hot water is a cost-effective approach to integrate buffer storage capacity. While the basic steam accumu...
متن کاملDirect Steam Generation with Dish Concentrators
This paper presents current research on Direct Steam Generation (DSG) by the Solar Thermal Group at ANU. It includes ongoing work on a transient model for a dish steam cavity receiver that is suitable for model-based control of DSG as well as reporting on the experimental set-up on a new 500m paraboloidal dish solar concentrator. A comparison of two transient models of a dish steam cavity recei...
متن کاملNumerical and Analytical Study of Natural Dry Cooling Tower in a Steam Power Plant
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...
متن کاملNumerical and Analytical Study of Natural Dry Cooling Tower in a Steam Power Plant
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Solar Energy
سال: 2011
ISSN: 0038-092X
DOI: 10.1016/j.solener.2010.10.005