منابع مشابه
Inferred pH in Steam Plant Water Chemistry
Inferred pH means pH calculated from straight and cation conductivity. The calculation can be applied to condensate, feedwater, and boiler water. Although not widely used in the United States, inferred pH is popular in Europe. Some plant chemists find inferred pH useful because it eliminates the need to measure pH directly, which without proper equipment can be a difficult task. This paper disc...
متن کاملPerformance Evaluation of Brewery Biological Wastewater Treatment Plant
Brewing is the process is for production of beer [1,2]. It is said that for every 1 liter of beer production approximate 10 liters of water is used [3]. The water in any brewery is typically used for brewing, rising and cooling process [3]. The various steps that are involved in brewing process are malt production and handling, worth preparation, fermentation, filtration, CIP and finally packag...
متن کاملPowering the porter brewery.
Before canals and railways developed as a major transport network, it was seldom profitable to transport beer inland over more than a few miles. In country towns and villages, therefore, beer would be brewed either by a small 'common' brewery that supplied a handful of pubs and private customers, or in an even smaller brew-house attached to the pub itself. Many families also brewed their own be...
متن کاملLinear Identification of a Steam Generation Plant
The paper examines the development of models of steam generation plant using linear identification techniques. The identification process is carried out using experimental data of a multi-input multi-output MIMO system representation. Various techniques of modeling and identification are applied considering the complete system as a MIMO model and studying the effect of all the inputs on individ...
متن کاملNumerical and Analytical Study of Natural Dry Cooling Tower in a Steam Power Plant
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Institute of Brewing
سال: 1934
ISSN: 0046-9750
DOI: 10.1002/j.2050-0416.1934.tb05530.x