Static-dynamic Tests of Bearing Capacity of Wind Turbine Piles
نویسندگان
چکیده
The paper presents the static load tests (SLT) and dynamic (DLT) of piles numerical analyses in interaction with soil wind turbines. Pile were conducted using equipment counter-weights for SLT an autonomous system control DLT piles. Numerical performed by signal matching method. Tests proved that design resistance mobilized are higher than forces obtained from turbine foundations. Also, need to develop a plan testing bearing capacity piles, concerning large significant buildings was emphasized.
منابع مشابه
Evaluation of Static and Dynamic Methods for Determining the Bearing Capacity of the Driven Pipe Piles (TECHNICAL NOTE)
Determination of the pile capacity is always a major concern for the safe geotechnical engineering design. Different direct and indirect methods have been proposed for determining pile bearing capacity such as static and dynamic approaches. Each method depends on the condition of the soil and type of pile as well as accessibility to necessary information. In this study bearing capacity of drive...
متن کاملstatic versus dynamic assessment of l2 learners’ reading ability
dynamic assessment according to vygotskys sociocultural theory, states that instruction and assessment are interrelated. using static forms of assessment with second and foreign language students could do more harm than good. many teachers neglect to take account of the complexity involved in learning a second or foreign language and often wonder why learning of a language take so long. thi...
Comparision of Methods for Determining Bearing Capacity of Piles Using Standard Penetration Test (SPT) Data
In recent years, determining bearing capacity of piles from in-situ testing data as a complement to static and dynamic analysis has been used by geotechnical engineers. In this paper, different approaches for estimating bearing capacity of piles from SPT data are studied and compared. A new method based on N value from SPT is presented. Data averaging, failure zone and plunging failure of pil...
متن کاملDynamic Stabilization of Wind Farms Deploying Static Synchronous Series Compensator
Encountering series-compensated transmission lines, sub-synchronous resonance (SSR) may strike the power system by jeopardizing its stability and mechanical facilities. This paper aims to verify the capability of static synchronous series compensator (SSSC) in mitigating the mechanical and electrical oscillations such as SSR in wind farm integrations. A wind turbine with a self–excited inductio...
متن کاملWind tunnel tests of a free yawing downwind wind turbine
This research paper presents preliminary results on a behavioural study of a free yawing downwind wind turbine. A series of wind tunnel tests was performed at the TU Delft Open Jet Facility with a three bladed downwind wind turbine and a rotor radius of 0.8 meters. The setup includes an off the shelf three bladed hub, nacelle and generator on which relatively flexible blades are mounted. The to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dokladi na B?lgarskata akademiâ na naukite
سال: 2022
ISSN: ['2367-5535', '1310-1331']
DOI: https://doi.org/10.7546/crabs.2022.10.13