Stand-alone system for high-resolution, real-time terahertz imaging
نویسندگان
چکیده
منابع مشابه
A Stand{Alone ASIC for Real{Time Edge Detection
In this paper, we present a stand alone ASIC architecture for a new edge detection algorithm, which applies the absolute diierence mask (ADM). The ASIC is built of three major blocks: smoothing, edge strength, and detection and localization blocks. To allow high{ speed processing, the architecture is nely pipelined. The proposed ASIC is capable of producing one edge{ pixel every clock cycle. At...
متن کاملUltrahigh Resolution OCT System for Real - time In Vivo Imaging
s and Conference Proceedings X. Li, T. H. Ko, and J. G. Fujimoto, “Intraluminal fiber optic Doppler imaging catheter for structural andfunctional optical coherence tomography,” Photonics West, SPIE, San Jose, CA, January 19-25, 2002,paper 4619-22. T. H. Ko, I. Hartl, W. Drexler, R. K. Ghanta, and J. G. Fujimoto, “Ultrahigh resolution optical coherencetomography for quantitative topo...
متن کاملHigh Resolution Waveguide Terahertz Time-Domain Spectroscopy
Terahertz time-domain spectroscopy accesses the frequency range between 100 GHz and 5 THz by using the coherent generation and detection based on femtosecond laser sources. On the way to obtain fingerprint absorption spectra of molecular solids, terahertz waveguides have proven to be a valuable tool to extend the results to narrow and high resolution linewidths of crystalline solids. We will di...
متن کاملReal-time broadband terahertz spectroscopic imaging by using a high-sensitivity terahertz camera
Terahertz (THz) imaging has a strong potential for applications because many molecules have fingerprint spectra in this frequency region. Spectroscopic imaging in the THz region is a promising technique to fully exploit this characteristic. However, the performance of conventional techniques is restricted by the requirement of multidimensional scanning, which implies an image data acquisition t...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2012
ISSN: 1094-4087
DOI: 10.1364/oe.20.002772