Stability indicating method development and validation for simultaneous estimation of atorvastatin calcium and celecoxib in bulk and niosomal formulation by RP-HPLC
نویسندگان
چکیده
منابع مشابه
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملSimultaneous RP-HPLC estimation and validation of ramipril and atorvastatin in bulk and combined tablet formulation
A simple, precise, accurate and reproducible RP-HPLC method was developed and validated for simultaneous estimation of ramipril and atorvastatin in bulk and combined pharmaceutical formulations. Separation of ramipril and atorvastatin was successfully achieved on an Inertsil ODS C18 column (150mm x 4.6mm x 5 μm). The mobile phase consisted of 0.1% ortho phosphoric acid and methanol (60:40, v/v)...
متن کاملStability Indicating Rp-hplc Method for the Simultaneous Determination of Olmesartan Medoxomil and Atorvastatin Calcium
A simple, rapid, and precise, stability indicating RP-HPLC method for simultaneous analysis of olmesartan medoxomil (OLM) and Atorvastatin (ATR) in bulk has been developed and validated. The analytes were separated by using a Waters symmetry C18 analytical column (250mm × 4.6mm, 5 μm) with a mobile phase consisting of Acetonitrile and 0.02 M potassium dihydrogen phosphate buffer containing 0.1%...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Brazilian Journal of Pharmaceutical Sciences
سال: 2015
ISSN: 1984-8250
DOI: 10.1590/s1984-82502015000300017