Stability-Indicating HPLC-DAD Determination of Ribavirin in Capsules and Plasma
نویسندگان
چکیده
منابع مشابه
Stability-indicating HPLC-DAD determination of ribavirin in capsules and plasma.
A simple, selective and stability-indicating high-pressure liquid chromatographic method was developed for the analysis of ribavirin. Chromatographic separation was achieved by using a CPS Hypersil cyano column (4.6 × 250 mm, 5 µm particle size) with isocratic elution of the mobile phase, which was composed of 50 mM phosphate buffer, adjusted at pH 4 with phosphoric acid. The mobile phase was p...
متن کاملStability-Indicating HPLC-DAD Method for the Determination of Granisetron Hydrochloride in Its Pharmaceutical Preparations
Article history: Received on: 15/03/2013 Revised on: 04/04/2013 Accepted on: 01/05/2013 Available online: A selective and reproducible high performance liquid chromatographic method has been developed for the determination of granisetron hydrochloride in presence of its hydrolytic, oxidation, photodecomposition and thermal degradation products. Successful separation of granisetron from its degr...
متن کاملA Stability Indicating HPLC Method for the Determination of Nitisinone in Capsules
In this study a simple and efficient stability-indicating HPLC method with short run time was developed for the determination of nitisinone. The stress degradation of nitisinone was studied in different acidic, basic, oxidative, thermal and photolytic conditions. The chromatographic separation was achieved on a Nova-Pak C18 column using a mixture of 50 mM NaH2PO4 (pH 2.5) and acetonitrile (45:5...
متن کاملStability-indicating MEKC method for determination of milnacipran in capsules
A stability-indicating method by micellar electrokinetic chromatography (MEKC) was developed and validated for determination of milnacipran (MNC) hydrochloride in capsules. The MEKC separation was performed in a fusedsilica capillary (40 cm x 50 μm i.d.), 30 kV voltage applied at 30 °C, using as background electrolyte solution 20 mM borate buffer (pH 8.8), 20 mM sodium dodecyl sulfate and detec...
متن کاملGradient HPLC-DAD stability indicating determination of miconazole nitrate and lidocaine hydrochloride in their combined oral gel dosage form.
The pharmaceutical combination of miconazole nitrate (MZ) and lidocaine hydrochloride (LD) is used in the curative and prophylactic therapy of the oral and gastro-intestinal infections caused by Candida albicans. To the best of our knowledge, no attempts have yet been made to assay this combination by any analytical method. A simple and selective high-performance liquid chromatography-diode arr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chromatographic Science
سال: 2013
ISSN: 0021-9665,1945-239X
DOI: 10.1093/chromsci/bmt067