Stability Assessment for Multi-Infeed Grid-Connected VSCs Modeled in the Admittance Matrix Form

نویسندگان

چکیده

The increasing use of power electronics converters to integrate renewable energy sources has been subject concern due the resonance oscillatory phenomena caused by their interaction with poorly damped AC networks. Early studies are focused assess controller influence a single converter connected simple networks, and they no longer representative for existing systems. Lately, multi-infeed grid-connected particular interest, main aim is apply traditional criteria identify difficulties in stability assessment. An extension commonly proposed as result these analysis, but can be burdensome large complex present work addresses this issue proposing criterion systems high-penetration converters. its origin mode analysis positive-net damping criteria, it frequency domain studying eigenvalues magnitude real component dynamic models admittance matrix form. Its effectiveness tested two case developed Matlab/Simulink which compare traditionally proving simplicity.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview

The interconnection stability of a grid-connected voltage-source converter (VSC) can be assessed by the passivity properties of the VSC input admittance. If critical grid resonances fall within regions where the input admittance acts passively, i.e., has nonnegative real part, then their destabilization is generally prevented. This paper presents an overview of passivity-based stability assessm...

متن کامل

Investigation of the Effect of Synchronization Techniques on the Stability of Grid-Connected Photovoltaic Systems

Abstract: Due to the increasing use of microgrids, investigation of their stability is of special interest. One of the disadvantages of an inverter-based distribution unit is that at any given time, phase and frequency information at the point of common coupling (PCC) is required that affected the stability. The synchronization techniques include synchronous reference frame phase-locked loop (S...

متن کامل

Stability Assessment Metamorphic Approach (SAMA) for Effective Scheduling based on Fault Tolerance in Computational Grid

Grid Computing allows coordinated and controlled resource sharing and problem solving in multi-institutional, dynamic virtual organizations. Moreover, fault tolerance and task scheduling is an important issue for large scale computational grid because of its unreliable nature of grid resources. Commonly exploited techniques to realize fault tolerance is periodic Checkpointing that periodically ...

متن کامل

Adaptive Sliding Mode Control of Multi-DG, Multi-Bus Grid-Connected Microgrid

This paper proposes a new adaptive controller for the robust control of a grid-connected multi-DG microgrid (MG) with the main aim of output active power and reactive power regulation as well as busbar voltage regulation of DGs. In addition, this paper proposes a simple systematic method for the dynamic analysis including the shunt and series faults that are assumed to occur in the MG. The pres...

متن کامل

Analysis of Failures in the Power Grid via the Pseudo-inverse of the Admittance Matrix

Recent large-scale power outages demonstrated the limitations of percolationand epidemic-based tools in modeling failures in power grids. Hence, we study the impact of line failures on the flow changes and cascade in the transmission system of the power grid by using a linearized power flow model. We use the pseudo-inverse of the power grid admittance matrix to obtain upper bounds on the flow c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Circuits and Systems I-regular Papers

سال: 2021

ISSN: ['1549-8328', '1558-0806']

DOI: https://doi.org/10.1109/tcsi.2021.3091938