Square-Wave Voltammetry of Cathodic Stripping Reactions. Diagnostic Criteria, Redox Kinetic Measurements, and Analytical Applications
نویسندگان
چکیده
منابع مشابه
Determination of abscisic acid by cathodic stripping square wave voltammetry.
In this paper a study is accomplished on behavior in a mercury electrode, of the phytohormone abscisic acid and of the conditions of accumulation in a HMDE. A mechanism is proposed of reduction based on its electrochemical behavior and proving the product of the reduction through mass spectrometry of bulks. A method is proposed for the determination of Abscisic acid (ABA) with a quantification ...
متن کاملDifferential pulse and square-wave cathodic stripping voltammetry of xanthine and xanthosine at a mercury electrode.
The surface activity of xanthine (Xan) and xanthosine (Xano) at a hanging mercury drop electrode (HMDE) was studied using out-of-phase ac and cyclic dc voltammetry. The results show that Xan and Xano were strongly adsorbed and chemically interacted with the charged mercury surface, which is the prerequisite step for applying the cathodic adsorptive stripping voltammetric determination of such b...
متن کاملDetermination of Aminophylline by Cathodic Stripping Voltammetry
Aminophylline is determined by cathodic stripping voltammetry (CSV) in BR buffer, pH 7.5 at a hanging mercury drop electrode. The detection limit was 3x10 M after 60 s accumulation at -0.60 V versus Ag/AgCl reference electrode. The linear range demonstrated up to 5x10 M using CSV. The interference caused by some purine derivatives, anions and some metal cations on the peak current was studied. ...
متن کاملDetermination of chitosan by cathodic stripping voltammetry.
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol l(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of C...
متن کاملAnalytical Utility of the Iridium-Based Mercury Ultramicroelectrode with Square-Wave Anodic Stripping Voltammetry
The characterktics of the irldium-based hemkphwkai mercury uitramlcrodectrode (Ha-UME) in conjunction with squarewave anodic stripping voltammetry (SWASV) have been Investigated. Udng Hg-UMEs of 5-10-pn~ radii, samples were analyzed without any added electrolyte, deoxygenatlon, or forced convectlon. The peak stripping currents displayed a linear rdation8hip with d.porltion times varying from 1 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electroanalysis
سال: 2004
ISSN: 1040-0397,1521-4109
DOI: 10.1002/elan.200302887