Spin-label oximetry at Q- and W-band
نویسندگان
چکیده
منابع مشابه
Spin-label saturation-recovery EPR at W-band: applications to eye lens lipid membranes.
Saturation-recovery (SR) EPR at W-band (94 GHz) to obtain profiles of the membrane fluidity and profiles of the oxygen transport parameter is demonstrated for lens lipid membranes using phosphatidylcholine (n-PC), stearic acid (n-SASL), and cholesterol analog (ASL and CSL) spin labels, and compared with results obtained in parallel experiments at X-band (9.4 GHz). Membranes were derived from th...
متن کاملBeam-Cavity Interaction Circuit at W-Band
We describe the design, fabrication and bench-study of a mm-wave cavity employed as a relativistic klystron output structure. The OFE copper cavity was prepared by electrodischarge machining and diffusion bonding, cleaned, and tuned to 91.4 GHz. Measured cavity characteristics are presented and compared with theory, including quality factor, Q, coupling parameter ß, scattering matrix S11, and a...
متن کاملBounding W-W' mixing with spin asymmetries at RHIC.
The W boson can obtain a small right-handed coupling to quarks and leptons through mixing with a hypothetical W^{'} boson that appears in many extensions of the standard model. Measuring or even bounding this coupling to the light quarks is very challenging. Only one model independent bound on the absolute value of the complex mixing parameter has been obtained to date. Here we discuss a method...
متن کاملSpin Dependent Nucleon Structure at Intermediate Q
This thesis focuses on hadronic spin structure at low and intermediate energies, 0 < Q2 < 3 GeV 2. The thesis is divided into two main sections. Each section addresses a different aspect of spin dependent hadronic physics which has not been studied previously in detail. The first section studies hydrogen hyperfine splitting. A polarizability term depending on the proton's G1 and G2 spin depende...
متن کاملMeasurement of Oscillator Phase and Amplitude Noise at W-band
This paper describes a technique used to measure oscillator noise sidebands at 94GHz. It is extendible to other frequencies in the millimetre-wave band. Oscillator noise sidebands are particularly significant for Continuous Wave (CW) radars, where the sidebands of the transmit/receive leakage can degrade the system noise figure. Measuring oscillator noise is also a particular challenge at highe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Magnetic Resonance
سال: 2011
ISSN: 1090-7807
DOI: 10.1016/j.jmr.2011.01.003