Simultaneous outer volume and blood suppression by quadruple inversion-recovery
نویسندگان
چکیده
منابع مشابه
Phase sensitive inversion recovery with simultaneous dark fat rendering by virtual chemical inversion
Background On delayed-enhancement (DE-CMR), both fat and infarcted myocardium appear bright making them difficult to differentiate. Standard chemical shift fat-suppression (FatSatCS) consists of a fat-frequency selective saturation followed by readout. This approach is suboptimal in clinical DE-CMR sequences which typically have long readout times (100-200ms) and as a result, fat magnetization ...
متن کاملAccelerated aortic plaque imaging using small field of view imaging and quadruple inversion recovery magnetization preparation
Introduction Autopsy data has demonstrated that the abdominal aorta offers a valuable early window for the study of atherosclerosis. Current MRI strategies often suffer from long scan times or require slice gaps. We sought to implement a small field-of-view approach (zoom imaging) (Buecker, A. et al, 1998), to allow complete coverage of the thoracic and abdominal aorta. To improve blood signal ...
متن کاملOptimized Outer Volume Suppression for Slice Selective MRSI
A. Henning, M. Schär, R. F. Schulte, K. P. Pruessmann, P. Boesiger Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Kanton Zurich, Switzerland, John Hopkins University, Baltimore, MD, United States Introduction In spite of significantly improved saturation pulses [1,2] sufficient outer volume (OVS) and especially fat suppression in MRSI could only be achieved in combinat...
متن کاملModified quadruple inversion recovery prepulse for arterial spin labeling angiography without the need of subtraction
Introduction Arterial Spin Labeling (ASL) is a well-known technique that allows the non-invasive acquisition of angiograms without the need of a contrast agent [1][2]. ASL angiography is still clinically underused because of several challenges [3]: ASL requires two acquisitions (labeled and non labeled dataset) thereby doubling scan time. The need of subtraction increases the sensitivity to spa...
متن کاملIntracranial vessel wall imaging with simultaneous blood and CSF suppression
Introduction: Recent studies suggested that the intracranial artery disease may have contributed to stroke and other clinical events more often than previous believes. Although non-invasive MR techniques have long been used to evaluate the extracranial arteries’ plaque burden and components, only a few techniques are at the clinicians’ deploy when studying the intracranial artery. One of the ke...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2006
ISSN: 0740-3194,1522-2594
DOI: 10.1002/mrm.20880