Simulation System for PeLUIt 150 MW Nuclear Reactor by using vPower
نویسندگان
چکیده
Abstract In developing the PeLUIt 150 MW nuclear power plant based on High Temperature Gas-cooled Reactor (HTGR) technology, with helium-coolant and output thermal of MW, simulator is also developed for training operators educating other technical personnel. Referred to balance (BOP) design PeLUIt, utilized vPower simulation platform simulate secondary loop generation a water-steam Rankine cycle. The paper focuses loop’s main components: steam generator, turbine, condenser, deaerator, feedwater pump. reactor module in primary simplified as heat source output. generator that connects loops modeled exchanger by transferring from helium water/steam. Meanwhile, pressure flow parameters can be simulated both water/steam flows steady-state transient operating conditions. results are almost same data. differences temperature, pressure, 0.03%, 0.53%, 0.02%, respectively. condition carried out loss coolant accident showed decrease flowrate 43.31 kg/s an increase temperature main-steam 52.32 15.38 °C, addition, there was drop around 10.37 (feedwater) 10.16 MPa (main-steam).
منابع مشابه
Nuclear Seawater Desalination Plant Coupled with 200 MW Heating Reactor
Feasibility study on nuclear seawater desalination plant in which a 200 MW nuclear heating reactor (NHR-200) couples with MED processes has being finished at Institute of Nuclear Energy Technology (INET) of Tsinghua university in China, the Chinese government has agreed to built the kind of nuclear seawater desalination plant in Shandong peninsula of China. Two different kinds of MED processes,...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولSensitivity analysis of reflector types and impurities in 10 MW MTR type nuclear research reactor
The 2-D and 3-D neutronics models for 10 MW nuclear research reactor of MTR type have been developed and presented in this paper. Our results agree very well with the results of seven countries mentioned in the IAEA-TECDOC233. To study the effect of reflector types on the reactor effective multiplication factor, five types of reflectors such as pure beryllium, beryllium, heavy water, carbon and...
متن کاملThe Design and Performance of 150-MW S-Band Wystrons
As part of an international collaboration, the Stanford Linear Accelerator Center (SLAC) klystron group has designed, fabricated and tested a 60 Hz, 3 W, 150 MW klystron built for Deutsches Elektronen Synchrotron (DESY). A test diode with a 535 kV, 700 A electron beam was constructed to verify the gun operation. The first klystron was built and successfully met design specifications. This paper...
متن کاملREACTOR: An Expert System for Diagnosis and Treatment of Nuclear Reactor Accidents
REACTOR is an expert system under development at EG&G Idaho, Inc., that will assist operators in the diagnosis and treatment of nuclear reactor accidents. This paper covers the background of the nuclear industry and why expert system technology may prove valuable in the reactor control room. Some of the basic features of the REACTOR system are discussed, and future plans for validation and eval...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of physics
سال: 2021
ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']
DOI: https://doi.org/10.1088/1742-6596/2048/1/012034